Steriflow Robustex 90L Saturated Steam Foe NGO
Meets the requirements of the NGOs in the area of emergency operation
• Robustex retort is entirely manually operated.
• All stainless construction AISI 304L.
• It is used by many NGOs worldwide.
Benefits
• Low investment.
• Optimum adaptation to very difficult conditions in the field.
• Very easy to use.
Product and packaging types
• Surgical instruments.
• Textiles.
• Stainless steel parts.
Related products
-
Steriflow Monofan Steristeam Air Steam
Static Monofan Air Steam
Filled retort baskets are inserted into the STERISTEAM. The door is closed then locked automatically through a hydraulic cylinder. The door is mechanically blocked throughout the entire cycle. Pre-heating of the enclosure is carried out by direct-steam-injection. Preheating temperature can be adjusted ((e.g. 100°C – 0.2 bar) and air vent valve open. Adjustable period (e.g. 5 minutes). Heating phase can be started. Heat is produced in the enclosure by directsteam-injection. Dissemination will be made between each basket. Graduated acting steam valve opening is monitored by MPI until the set temperature is reached, for instance 121°C. In this heating-up phase, the fan is on. The operation of the fan is continually monitored. Condensates are stored in the lower part of the enclosure. Once the scheduled duration of the bearing comes to an end : pre-cooling starts. It is performed by injecting cold water in the vessel via two lateral spray headers. This water accumulates at the lower section in addition to the condensates previously accumulated. The water level is controlled by a radar level and managed by MPI. Once the set temperature is reached, final cooling is carried out by cascading recycled water on the load. How does the cascading system operates ? Recycled water is made with steam condensate previously accumulated in previous phases as well as water make up. The mixture is pumped at the sterilizer lower section through the secondary circuit of an external heat exchanger (plates and gaskets), and returned on water distributor laid out on top of the load to cool.Technical specifications :
Standard diameters:
• 1,300 mm.
• 1,450 mm.
• 1,600 mm.
• 1,800 mm.
• 2,000 mm.Benefits
• Perfect reproducibility of the programmed cycles.
• Homogeneity of treatment with a powerful fan.
• A proven and reliable design with all common diameters.
• Powerful cooling system to optimize the cycle time.
• Ability to dry product at the end of the cycle.Product and packaging types
• Bags of saline solution
• Blister packQuick View -
Steriflow Saturated Steam
Saturated Steam Autoclave
It is particularly well-adapted for all the decontamination processes in the pharmaceutical industry (opened bottles, instruments, Petri dishes, textiles…). All products are sterilized with the use of pure steam. At the beginning of the cycle the air from the tank is removed by the vacuum pump (2 to 3 vacuum cycles). Then the steam is introduced at the appropriate pressure (or temperature) to sterilize the product. The heating level is met. Various phases are usually repeated 2 to 3 times. Refrigeration is realized through internal exchangers and by vacuum drying (evaporation).Technical characteristics:
• Material: stainless steel 304L or 316L.
• Diameter: 900 mm. (capacity from 200 L.) and 1300 mm. up to 2000 mm.
• Capacity: from 2oo L.Benefits
• Pure steam sterilization with vacuum system.
• Quick refrigeration through drying, internal exchangers and final vacuuming.Product and packaging types
• Opened bottles.
• Instruments.
• Petri dishes
• TextilesQuick View -
Steriflow Static Cascading Water
Steriflow Static for the discharge of superheated water
Each cycle takes place automatically, in conformity with the saved parameters, including highly accurate control of air back-pressure regardless of the temperature. Water is sprayed over the products to be treated with great intensity. The hydraulic circuit of water in S* takes place as follows: pumping, Platular® exchange, douching arrangement, water flow over the products, douching and filtration arrangement, pumping. STERIFLOW water flow system allows the refrigeration of products, using sterile water.
This autoclave is perfectly adapted for < 105°C processes.Technical specifications :
Standard diameters:• 900 mm.
• 1,300 mm.
• 1,450 mm.
• 1,600 mm.
• 1,800 mm.
• 2,000 mm.
• 2,100 mm (the first of its category in 1982),
• 2,300 mm (the first in 1984).
• Capacity from 2 to 7 baskets (depending on diameter).Benefits
• Perfect reproducibility of the programmed cycles.
• Air back-pressure management regardless of the temperature.
• Minimal maintenance costs.
• Designed in a way that maximally reduces the amount of liquid used in the process.Product and packaging types
All types of packaging including:• large pouches
• Non-PVC pouches
• Glass or plastic ampoules
• Bottles
• Glass bottlesQuick View